Wet Calibration of Tank Farm
On site calibration of Instrumentation in Northern Ireland Pharmaceutical Industry
The Project..
Our Instrumentation engineers have been on site at a major Northern Ireland pharmaceutical company performing a wet calibration off a tank farm.
Level Flex FMP51-52NR8/0 fitted to a 60,000L storage tank.
Meeting the clients requirements
Ashdale were employeed to
conduct wet calibration for accurate fill volume measurement across the full volume of the tank.
32 point tank linearisation table generated for accurate fill height to fill volume conversion.
4-20 mA signal scaled to accurately represent 0-60,000 L fill volume of the non linear horizontal cylindrical tank.
Primary Equipment used
Endress + Hauser Promag H 300 mag flowmeter used to accurately measure water as it is pumped into the tank
Ashdale are proud to represent Endress+Hauser in Northern Ireland.